Cisco 010-151 Free Practice Questions

Q1. Refer to the exhibit. 

Where is the best place to find the B200 BIOS version used in a specific Cisco UCS Manager version? 

A. A - Installed Firmware 

B. B - Packages 

C. C - Images 

D. D - Capability Catalog 

E. E - Management Extension 

Answer:

Q2. Which method is a TCP/IP-based protocol for establishing and managing connections between IP-based storage devices, hosts, and clients? 

A. FCIP 

B. iFCP 

C. iSCSI 

D. FCoE 

Answer:

Q3. Which command can be used to exit to EXEC mode from this current mode? 

switch(config-if) # 

A. Ctrl-C 

B. Ctrl-L 

C. quit 

D. exit 

E. end 

Answer:

Q4. Which method does FCIP use to enable connectivity of geographically distributed Fibre Channel SANs over IP? 

A. routing 

B. tunneling 

C. handshaking 

D. transporting 

Answer:

Q5. Where do you find the model number of a Cisco MDS 9200 Series chassis? 

A. on the top front of the chassis next to the serial number 

B. on the bottom front of the chassis next to the Cisco logo 

C. on the top front of the chassis next to the Cisco logo 

D. on the bottom front of the chassis next to the serial number 

Answer:

Q6. Refer to the exhibit. 

Which statement correctly identifies the front panel LEDs on the Cisco UCS C220 Server? 

A. A is power button and power status LED; B is identification button and LED; C is system status LED; D is network link activity LED. 

B. A is network link activity LED; B is system status LED; C is power button and power status LED; D is identification button and LED. 

C. A is system status LED; B is network link activity LED; C is power button and power status LED; D is identification button and LED. 

D. A is network link activity LED; B is system status LED; C is identification button and LED; D is power button and power status LED. 

Answer:

Q7. Which Cisco Nexus 5000 Series model supports 1/10G BASE-T ports? 

A. Cisco Nexus 5548P 

B. Cisco Nexus 5548UP 

C. Cisco Nexus 5596UP 

D. Cisco Nexus 5596T 

Answer:

Q8. Which action should the administrator take before physically removing a blade server for maintenance or replacement? 

A. Force the server to shut down. 

B. Disassociate the service profile. 

C. Decommission the server. 

D. Perform a graceful shutdown of the server. 

Answer:

Q9. Which type of connection across the network does a SAN allow for multiple servers to access an unlimited amount of storage devices? 

A. any-to-many 

B. many-to-any 

C. any-to-any 

D. any-to-one 

E. one-to-any 

F. one-to-one 

Answer:

Q10. Refer to the exhibit. 

This image shows a CPU Pick-and-Place tool and a CPU Socket Protective Cap Removal tool. 

Which types of Cisco UCS servers and Intel Xeon processors do these tools support? 

A. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5-2400 Series processors 

B. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5-2600 Series processors 

C. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2400 Series processors 

D. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2600 Series processors 

Answer:

Q11. Which two statements about DIMM replacement in Cisco UCS Servers are true? (Choose two.) 

A. In blade servers, DIMMs can be installed in either 1, 2, 4, or 8 DIMMs per channel. 

B. Rack-mount and blade servers have memory fault LEDs that indicate which DIMM requires attention. 

C. In servers that require pairs of DIMMs, the pairs must be identical (manufacturer, size, part #, and so on). 

D. If the memory in a server is not fully populated, you can install DIMMs in any open slot. 

Answer: A,C 

Q12. Which two commands display the version of Cisco NX-OS code that the device is currently running on? (Choose two.) 

A. show version 

B. show module 

C. show interface 

D. show boot 

E. show license 

Answer: A,B 

Q13. Which Cisco MDS model supports the most Fibre Channel ports per chassis? 

A. MDS 9513 

B. MDS 9509 

C. MDS 9506 

D. MDS 9250i 

Answer:

Q14. Which two statements about PCIe are true? (Choose two.) 

A. The PCIe link is built around dedicated unidirectional couples of serial, point-to-point connections known as lanes. 

B. You can install a PCI Express x8 adapter into an x4 slot. 

C. The PCIe standard is a bus-based system in which all the devices share the same bidirectional, 32-bit or 64-bit, parallel signal path. 

D. The PCIe 1.0 standard doubles the transfer rate compared to PCIe 2.0. 

E. A link that is composed of four lanes is called an x4 link. 

Answer: A,E 

Q15. Which fiber optic cable type is used most often with a Subscriber connector? 

A. dual-mode 

B. single-mode 

C. straight-mode 

D. multi-mode 

E. subscriber-mode 

Answer:

Q16. Which three firmware components does the Host Upgrade Utility upgrade? (Choose three.) 

A. Fabric Interconnect firmware 

B. LAN on Motherboard 

C. Cisco UCS Manager 

D. CIMC 

E. System BIOS 

Answer: B,D,E 

Q17. Which two remote file system methods are used in the training material to transfer firmware to the Fabric Interconnect? (Choose two.) 

A. FTPS 

B. FTP 

C. TFTP 

D. RSH 

Answer: B,C 

Q18. On the Sensors page from the CIMC view, which four tabs are displayed to view further information? (Choose four.) 

A. Power Supply 

B. Fan 

C. Memory 

D. CPU 

E. LEDs 

F. Temperature 

Answer: A,B,E,F 

Q19. Which two major components does a Cisco Nexus 1000V Series Switch have? (Choose two.) 

A. Virtual Fiber Channel Module 

B. Virtual Ethernet Module 

C. Virtual Supervisor Module 

D. Virtual Memory Controller Module 

E. Virtual Network Module 

Answer: B,C 

Q20. Refer to the exhibit. 

Which call-out accurately shows the current running version of the Cisco UCS Manager management software? 

A. A - UCS Manager running version 1.4(1m) 

B. B - IO Module 1 running version 1.4(1m) 

C. C - Interface Card 1 running version 1.4(1m) 

D. D - Kernel running version 4.2(1)N(1.4m) 

Answer:

Q21. Which five things should the administrator verify after performing maintenance or replacing a blade server? (Choose five.) 

A. blade server status 

B. hard drive status 

C. host OS boot status 

D. CPU status 

E. mezzanine card status 

F. memory DIMM status 

G. fan and power status 

Answer: A,B,D,E,F 