Want to know Testking 1z0-485 Exam practice test features? Want to lear more about Oracle Oracle Exadata Database Machine 2014 Implementation Essentials certification experience? Study Verified Oracle 1z0-485 answers to Replace 1z0-485 questions at Testking. Gat a success with an absolute guarantee to pass Oracle 1z0-485 (Oracle Exadata Database Machine 2014 Implementation Essentials) test on your first attempt.
Free demo questions for Oracle 1z0-485 Exam Dumps Below:
NEW QUESTION 1
Exadata Database Machine offers an Intelligent Platform Management Interface for the various components in the Exadata product. Which option is true?
Answer: A
Explanation:
IPMI – short for Intelligent Platform Management Interface - is an interface standard that allows remote management of a server from another using standardized interface. The servers in the Exadata Database Machine follow that. It’s not an Exadata command but rather a general Linux one.
To power on a cell or database server, issue this from another server:
# ipmitool -H prolcel01-ilom -U root chassis power on
To stop a server, use the shutdown command. To stop immediately and keep it down, i.e. not reboot, execute:# shutdown -h -y now
NEW QUESTION 2
The Exadata compute node, exadbs04, has been having issues for some time. The server had to be repaired and you just received a new server. Your LVM snapshot was corrupt and now the compute node must be re-image with an Oracle Support installation image. Which three tasks would you need to perform to re-image the compute node?
Answer: BCE
Explanation:
C: Exadata provides a way for you to create your own CELLBOOT USB. All you have to is plug-in a USB disk which should be at least 1 GB and run the tool:
$ /opt/oracle.SupportTools/make_cellboot_usb
Exadata turns your USB disk into a bootable disk of active image of your system.
NEW QUESTION 3
Which statement is true about the patching features provided in Platinum Services?
Answer: D
Explanation:
* Patch Deployment: Oracle Platinum Services also includes patching services in which Oracle
applies patches to covered systems four times (not A) per year via the Oracle Advanced Support
Gateway. We work collaboratively with customers to assess, analyze, plan and deploy updates
and patches to mitigate risks and complications. Through this continuous improvement, customers can experience greater system performance, availability, and security.
* not B: Oracle Platinum Services provides enhanced support for high availability and performance to Oracle Premier Support customers
running certified configurations of Oracle Exadata Database Machine, Oracle Exalogic Elastic Cloud, or Oracle SuperCluster—at no additional cost.
NEW QUESTION 4
Which two statements are true about enabling write-back flash cache?
Answer: BC
Explanation:
B: Exadata storage version 11.2.3.2.1 is the minimum version required to use this write back flash cache option.
C: Steps for Enabling Write back flash cache:
First of all, you don’t need the stop CRS or database (This is ROLLING method) ,you can do it cell by cell.
* drop flashcache
* Be sure asmdeactivationoutcome is YES is before disabling grid disk
NEW QUESTION 5
Which statement is true about Exadata Storage Servers?
Answer: C
Explanation:
Incorrect:
Not B: Only on database servers.
not D: Exadata Storage Servers have dual 40 Gigabit InfiniBand links that provide connectivity
many times faster than traditional storage or server networks.
NEW QUESTION 6
Your customer would like to use DBFS in their Exadata environment. They are asking you for the key characteristic of DBFS on Exadata.
Answer: B
NEW QUESTION 7
Identify two reasons why using external tables for high performance data loads on Exadata is more advantageous than SQL*Loader.
Answer: C
Explanation:
Parallelizing loads with external tables enables a more efficient space management
compared to SQL*Loader, where each individual parallel loader is an independent database sessions with its own transaction.
NEW QUESTION 8
Which three statements are true about Automatic Degree of Parallelism (Auto DOP) on Exadata?
Answer: BDE
Explanation:
B (not c): To enable the features in 11g Release 2, use the parallel_degree_policy parameter (by default this stuff is off - parameter is set to manual). For Auto DOP, setting this to limited is sufficient. If you want more functionality (in-memory parallel processing and parallel statement queuing parallel_degree_policy should be set to auto).
Incorrect: Not A:
* What if you don’t have Exadata? Chances are that if your system is large enough to warrant Auto DOP, it is similar enough to Exadata to behave nicely with this number.
* Auto DOP is only useful in systems with enough CPUs and disks to make concurrent parallel processing feasible. It was designed mostly for Exadata, or for systems of similar size. 48 CPUs and 84 disks sound like a nice start
NEW QUESTION 9
Which three migration options are available when you migrate a database from the Big Endian format system to Exadata?
Answer: BCD
Explanation:
Methods at a Glance:
* Data Guard Physical Standby
* Transportable Database (Note:732053.1)
* Transportable Tablespace (TTS)
NEW QUESTION 10
Identify the three values to which the cell_flash_cache attribute can be set.
Answer: CDE
Explanation:
There are three values the CELL_FLASH_CACHE attribute can be set to.
DEFAULT specifies the cache used for a DEFAULT object is automatically managed as described in the previous section. NONE specifies that the object will never be cached. KEEP specifies the object should
be kept in cache.
Note: The CELL_FLASH_CACHE can be assigned to a database table, index, partition and LOB column.
NEW QUESTION 11
Consider the following software changes that are performed manually on a Linux server:
1. Changes for Linux kernel firewall configuration
2. Changes for custom performance monitoring tools
3. Changes for security scan tools
4. Changes for Linux system performance optimization
Which of the software changes listed are permitted on Exadata Storage Servers?
Answer: E
Explanation:
1: The Storage Server Patch is responsible for keeping our cell nodes always up-to-date, fixing possible problems, and this patch includes different component patches, like kernel patches, firmware, operation system, etc… for the Storage Server.
Incorrect:
3,4: security scan tools changes and Linux system performance optimization changes would be on the database server.
NEW QUESTION 12
Identify four significant changes when a backup of Exadata compute nodes must be performed.
Answer: ACDG
NEW QUESTION 13
You are conceh is the best location to point your customer to, for finding the latest Exadata prned about how recovery from a failed Exadata Storage Server would work. Which statement is true about the Exadata CELLBOOT USB?
Answer: AC
Explanation:
A (not B, not E): Oracle automatically performs backups of the operating system and cell software on each Exadata Storage Server. The contents of the system volumes are automatically backed up and require no Oracle DMA intervention or operational processes. Oracle assumes responsibility for backing up the critical files of the storage cells to an internal USB drive called the CELLBOOT USB Flash Drive.
C:
Note: The ipconf utility is installed in /opt/oracle.cellos on both the Exadata Storage Servers and Compute Nodes and is symbolically linked to /usr/local/bin/ipconf. ipconf is called at system startup time to set and validate your Exadata server network information.
NEW QUESTION 14
How would you execute CellCLI commands and scripts?
Answer: D
Explanation:
The storage cells in Exadata Database Machine are managed via two tools called CellCLI and DCLI.
NEW QUESTION 15
You get a Host Unreachable error when you attempt to connect to a server through a network terminal command line. What are two other ways in which you can connect?
Answer: AC
Explanation:
In addition to gaining shell access via SSH to manage your Exadata servers, you can also access them from the Integrated Lights Out Management (ILOM) console or KVM console.
and should typically not require modifications unless you have changed network information inside your database
machine.
Note: A KVM switch (with KVM being an abbreviation for "keyboard, video and mouse") is a hardware device that allows a user to control multiple computers from one or more[1] keyboard, video monitor and mouse. Although multiple computers are connected to the KVM, typically a smaller number of computers can be controlled at any given time
NEW QUESTION 16
Which Exadata feature uses Flash as a parallel write cache to Disk Controller Cache?
Answer: D
Explanation:
Smart Flash Logging takes advantage of the flash memory in Exadata storage to speed up log writes.
NEW QUESTION 17
What are three ways to be informed of an Exadata Storage Server disk failure?
Answer: ADE
Explanation:
A: A disk status change would be associated with an entry in the storage cell alerthistory.
D: The Cell Alert Delivery Configuration Worksheet allows you to provide SMTP details to allow for e-mail communication of various cell alerts and failures.
Incorrect:
Not F: Use the iostat command to report statistics about disk input and output, and to produce measures of throughput, utilization, queue lengths, transaction rates, and service time.
NEW QUESTION 18
Which statement is true about Oracle compression?
Answer: CD
Explanation:
C: • Tables are organized by column and compressed. This makes it much easier to get similar
values together, which enhances the compression greatly. D: It is recommended that HCC be enabled on tables or partitions with no or infrequent DML operations. If frequent DML operations are planned on a table or partition, then the Oracle Advanced Compression Option is better suited for such data.
NEW QUESTION 19
Why is ASM High redundancy an important configuration choice when rolling Exadata Storage Server patching is planned?
Answer: A
Explanation:
To ensure redundancy during a rolling upgrade of the Exadata Storage Server Software, MAA recommends ASM high redundancy disk groups.
NEW QUESTION 20
Which CellCLI command is used to conclude that a storage server can be taken offline without impacting database availability?
Answer: A
Explanation:
ASMDeactivationOutcome – recall that grid disks can be deactivated, which is effectively taking them offline. Since ASM mirroring ensures that the data is located on another disk, making this disk offline does not lose data. However, if the mirror is offline, or is not present, then making this grid disk offline will result in loss of data. This attribute shows whether the grid disk can be deactivated without loss of data. A value of “Yes” indicates you can deactivate this grid disk without data loss.
CellCLI> list griddisk attributes name, ASMDeactivationOutcome, ASMModeStatus DBFS_DG_CD_02_cell01 Yes ONLINE
DBFS_DG_CD_03_cell01 Yes ONLINE DBFS_DG_CD_04_cell01 Yes ONLINE
… output truncated …
NEW QUESTION 21
You are measuring the I/O savings provided by storage indexes for Table A. One of your scripts displays the I/O savings as a result of the storage indexes. Which two statements are true?
SQL> select count (*) from transmap.mymap_comp 2 where map_id between 400 and 500;
COUNT(*)
103000
Elapsed: 00:00:00.08
SQL> select b.name, a.value/1024/1024 value from vSmystat a, vSstatname b,
where b.statistic# = a.statistic#
and b.nafne in (•cell physical IO bytes eligible for predicate offload',
•cell physical IO interconnect bytes',
•cell physical IO bytes saved by storage index',
•cell physical IO interconnect bytes returned by smart scan') order by 1;
Statistic Value (MB)
--------------------------------------------------------------------------------------------- -----------------
cell physical IO bytes eligible for predicate offload 2,255 .09 cell physical IO bytes saved by storage index .00
cell physical IO interconnect bytes 1.72
cell physical IO interconnect bytes returned by smart scan 1.68
Answer: BC
Explanation:
* cell physical I/O bytes eligible for predicate offload Number of bytes eligible for predicate offload, an indication of smart scan
* (not D) cell physical I/O bytes saved by storage index Here 0.
Number of bytes saved by a storage index; this is a reflection of how many physical disk I/O bytes (and by proxy, requests) were saved due to a storage index eliminating candidate blocks
NEW QUESTION 22
Which two statements describe correct network configuration for Exadata Database Machine?
Answer: CD
Explanation:
Incorrect:
Not A: The InfiniBand switches use an OpenSMInfiniBand subnet manager to manage the switch configuration.
NEW QUESTION 23
When an Exadata Storage Server hard disk failure alert is received, what manual action must you take to restore the system to full redundancy?
Answer: C
Explanation:
As soon as the Hard Disk failure is noticed by the MS (Management Server) background process on the Cell, it will raise an alert that will also be published to Grid Control, if configured. Immediately, due to Pro-Active Disk Quarantine, the ASM-, Grid- and Celldisks get dropped. ASM rebalancing is triggered. You as the responsible Admin notice the alert and order a replacement Disk resp. use a Spare Disk to plug it into the Cell after you plugged out the damaged one. The Cell can stay online, because the Hard Disks are hot-pluggable.
No further administrative work to be done, typically.
NEW QUESTION 24
Which two statements are true about CellCLI?
Answer: BD
Explanation:
B:
* Making a grid disk inactive effectively offlines its associated ASM disk.
CellCLI> alter griddisk PRORECO_CD_11_cell01 inactive GridDisk PRORECO_CD_11_cell01 successfully altered
* The command will wait until the ASM disk becomes offline. If you want the prompt to come back immediately without waiting, you can use nowait clause.
CellCLI> alter griddisk PRORECO_CD_11_cell01 inactive nowait You can make it active again:
CellCLI> alter griddisk PRORECO_CD_11_cell01 active GridDisk PRORECO_CD_11_cell01 successfully altered Incorrect:
not E: CellCLI> list physicaldisk detail output include:
physicalSerial: XXXXXX
NEW QUESTION 25
......
100% Valid and Newest Version 1z0-485 Questions & Answers shared by Surepassexam, Get Full Dumps HERE: https://www.surepassexam.com/1z0-485-exam-dumps.html (New 71 Q&As)