300-175 Premium Bundle

300-175 Premium Bundle

DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) Certification Exam

4.5 
(44700 ratings)
0 QuestionsPractice Tests
0 PDFPrint version
November 21, 2024Last update

Cisco 300-175 Free Practice Questions

Act now and download your today! Do not waste time for the worthless tutorials. Download with real questions and answers and begin to learn with a classic professional.

Free 300-175 Demo Online For Microsoft Certifitcation:

NEW QUESTION 1
Which statement about high-availability clusters for Cisco UCS Fabric Interconnects is true?

  • A. Peers in a cluster must connect to each other by using two 10-Gbps links.
  • B. The cluster requires a minimum of two IP addresses.
  • C. The management plane is active/standby.
  • D. The data plane is active/standby.

Answer: C

Explanation: Reference:
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/20/b_UCSM_GUI_Configura

NEW QUESTION 2
Which two statements about Cisco VM-FEX dynamic vNIC configuration and provisioning by using the Cisco UCS Manager are true? (Choose two.)

  • A. Dynamic vNIC parameters are configured by using SNMP.
  • B. Dynamic vNIC parameters must be configured manually before the virtual machine connects to its port group.
  • C. Dynamic vNIC parameters are configured dynamically after the assigned virtual machine connects to the port group.
  • D. Dynamic vNIC parameters are enabled by using the Fibre Channel Forwarder protocol.
  • E. Dynamic vNIC parameters are configured by inheriting the port-group parameters of the associated virtual machines.

Answer: CD

Explanation: Reference: http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/mkt_ops_guides/513_n1_1/n5k_ops_vmfex.pdf

NEW QUESTION 3
You need to configure a new Fibre Channel port channel from the Cisco UCS Manager GUI. To do this, from the SAN tab, you navigate to SAN Cloud > Fabric A or B > FC Port Channels, and you click the plus sign. In the popup window, you specify the Fibre Channel port channel name and ID.
Which two rules should you follow when you set the Fibre Channel port channel name and ID? (Choose two.)

  • A. The Name field must be a number.
  • B. The ID field can contain ASCII characters, except for spaces.
  • C. The Name field is optional, but it cannot contain spaces.
  • D. TheFibre Channel port channel ID is optional.
  • E. TheFibre Channel port channel ID must be a number.

Answer: CE

Explanation: The identifier for the port channel.
Enter an integer between 1 and 256. This ID cannot be changed after the port channel has been saved. Name field A user-defined name for the port channel.
This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and . (period), and you cannot change this name after the object has been saved.
The Fibre Channel port channel ID is NOT optional
The ID field CANNOT contain ASCII characters, OR spaces. The Name field must be a number IS NOT CORRECT.
The Fibre Channel port channel ID must be a number. IS CORRECT The Name field is optional, but it cannot contain spaces. IS CORRECT
The name field is optional (notice the "Next >" button is available when the name field is empty.

NEW QUESTION 4
Which three components are parts of the Cisco UCS -Series Blade Server software bundle? (Choose three.)

  • A. the adapter firmware
  • B. the Kernel and system firmware for fabric interconnects
  • C. the BIOS firmware
  • D. the IOM firmware
  • E. the Cisco UCS Manager software
  • F. the board controller firmware

Answer: ACF

Explanation: Reference:
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-2/b_GUI_Firmware_Ma

NEW QUESTION 5
Which Cisco UCS firmware are contained in the Cisco UCS Infrastructure software bundle? (Choose three.)

  • A. Cisco UCS BIOS
  • B. Cisco UCS fabric interconnects firmware
  • C. Cisco UCS adapters
  • D. Cisco UCS Manager
  • E. Cisco I/O module firmware
  • F. Cisco IMC

Answer: BDE

NEW QUESTION 6
Which option describes the possible result of a customer configuring a server pool that contains Cisco UCS B200 M2 and B250 M2 blades?

  • A. A service profile cannot migrate automatically from one blade to another blade within the server pool due to hardware failure.
  • B. You must decommission a blade server for the associated service profile to migrate to another blade in the server pool successfully.
  • C. You must uncheck the Restrict Migration box in the service profile to allow service profile migration between blades in the server pool.
  • D. After service profile migration, the server fails in boot from SAN due to differences in PCI device IDs.

Answer: D

NEW QUESTION 7
You must implement a Dynamic FCoE topology that uses ECMP. Which ancillary technology do you use?

  • A. OTV
  • B. VXLAN
  • C. FabricPath
  • D. EIGRP

Answer: C

NEW QUESTION 8
ACisco UCS Administrator is planning to complete a firmware upgrade using Auto install. Which two optionsare prerequisites to run Auto Install? (Choose two.)

  • A. Minor fault fixing
  • B. Configuration backup
  • C. Service profiles unmounted from the blade servers
  • D. Time synchronization
  • E. Fault suppression started on the blade servers

Answer: BD

Explanation: Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-2/b_GUI_Firmware_M

NEW QUESTION 9
Which three items must be configured in the Port Profile Client in Cisco Unified Computing System Manager? (Choose three.)

  • A. port profile
  • B. DVS
  • C. data center
  • D. folder
  • E. VMware vCenter IP address
  • F. VM port group

Answer: BCD

NEW QUESTION 10
Which destination(s) are valid for syslog messages for a Cisco UCS Fabric Interconnect?

  • A. the log, the monitor and syslog queue
  • B. a file
  • C. the console and log only
  • D. the console, the monitor, and a file

Answer: D

Explanation: http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/ucsm_syslog/b_Monitoring_Cisco_UCSM_Us

NEW QUESTION 11
Which statement about Cisco Integrated Management Controller secure mode is true?

  • A. After you enable it, you cannot disable it.
  • B. After you enable it, you cannot downgrade the Cisco Integrated Management Controller firmware.
  • C. It verifies the OS before allowing it to boot.
  • D. The server must reboot to apply.

Answer: A

NEW QUESTION 12
Which two protocols does the Cisco Integrated Management Controller support for managing standalone Cisco UCS C-Series servers? (Choose two.)

  • A. SMASH CLP
  • B. IPMIv2
  • C. SoL
  • D. SNMPv3
  • E. Virtual KVM

Answer: BD

Explanation: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-servers/ata- The IMC supports industry-standard protocols, including Redfish version 1.01, Intelligent Platform
Monitoring Interface Version 2 (IPMI v2), and Simple Network Management Protocol versions 2 and 3 (SNMP v2 and v3). It also provides an open Extensible Markup Language (XML) API and a command-line interface (CLI).

NEW QUESTION 13
Refer to the Exhibit:
300-175 dumps exhibit
Refer to the exhibit. Which action do you take to ensure that the IP addresses in IP pool ext-mgmt are selected in a random order?

  • A. Select the Default option in the Assignment Order property
  • B. Delete all the IP pools except for IP pool ext-mgmt
  • C. Add another block to IP pool ext-mgmt
  • D. Select a pool size that is larger than 0

Answer: A

NEW QUESTION 14
Which two components can be specified in a host firmware package? (Choose two.)

  • A. CPU
  • B. BIOS
  • C. Cisco Integrated Management Controller
  • D. LOM
  • E. DIMM

Answer: BC

NEW QUESTION 15
300-175 dumps exhibit
300-175 dumps exhibit

    Answer:

    Explanation: The cluster will switch fabric interconnect b from subordinate to lead or primary.

    NEW QUESTION 16
    Scenario
    In this scenario, you will refer to screenshots about Cisco UCS B-Series servers and UCS Manager. Instructions
    To access the multiple-choice questions, click on the numbered boxes on the left of the top panel. There are four multiple-choice questions with this task. Be sure to answer all four questions before selecting the Next button.
    300-175 dumps exhibit
    300-175 dumps exhibit
    300-175 dumps exhibit
    Refer to the screenshot in Exhibit 3. Which tab would you choose to determine that a user failed to login to Cisco IMC?

    • A. Fault Summary
    • B. System Event Log
    • C. CIMC Log
    • D. Logging Controls

    Answer: C

    Explanation: Reference:
    http://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/gui/config/guide/1.5/b_Cisco_UCS_C-series_G

    NEW QUESTION 17
    Which three statements about default settings for fabric interconnect uplink ports are true? (Choose three.)

    • A. When a VLAN is configured, it is trunked on all uplinks.
    • B. Specific VLANs are trunked on specific uplinks.
    • C. UDLD is enabled.
    • D. UDLD is disabled.
    • E. Cisco Discovery Protocol is enabled.
    • F. Cisco Discovery Protocol is disabled.
    • G. They connect to the I/O modules.

    Answer: ADE

    NEW QUESTION 18
    300-175 dumps exhibit
    300-175 dumps exhibit

      Answer:

      Explanation: 1

      NEW QUESTION 19
      Which of the following is true with respect to hardware failover or NIC teaming within a Cisco Unified Computing System?

      • A. Hardware failover is specified by the operating system.
      • B. An uplink failure when using automatic pinning requires that hardware failover for the server vNIC be disabled.
      • C. NIC teaming is controlled by the vNIC.
      • D. The hardware failover option that is available for Ethernet does not affect Fibre Channel traffic.

      Answer: D

      P.S. Easily pass 300-175 Exam with 349 Q&As Certleader Dumps & pdf Version, Welcome to Download the Newest Certleader 300-175 Dumps: https://www.certleader.com/300-175-dumps.html (349 New Questions)


      START 300-175 EXAM