P.S. Printable 3V0-624 prep are available on Google Drive, GET MORE: https://drive.google.com/open?id=1eINzd6M2vOHYKJToFohMz1RDsHdhNblV
Q1. After the vSAN iSCSI Target service is enabled, which statement about iSCSI networks is true?
A. A separate VMkernel interface may be configured per target.
B. A single VMkernel interface must be selected for all iSCSI targets.
C. The vSAN iSCSI Target service always uses all Management VMkernel interfaces.
D. The vSAN iSCSI Target service always uses the vMotion network.
Answer: A
Q2. Drag each option to its appropriate concept.
Answer:
Q3. The customer has two sites that must operate independently of each other in the event of a WAN failure. During normal operations, administrators from each site must be able to manage the other site through the vSphere Web Client.
Which vCenter Server Appliance (VCSA) and Platform Services Controller (PSC) diagram shows the VMware-recommended design that satisfies these requirements?
A. Exhibit A
B. Exhibit B
C. Exhibit C
D. Exhibit D
Answer: D
Q4. A developer is tasked with building an application to process shipping requests. The developer is consulting the vSphere team to determine failover options and performance best practices.
u2022 The development team is providing three physical ESXi hosts with 8 CPU cores and 256G8 of RAM per host.
u2022 The developer does NOT know how many virtual machines they will require.
Which virtual machine (VM) sizing strategy will provide the highest level of uptime, individual VM performance, and failover capacity?
A. A few large 8 vCPU VMs per host protected by vSphere HA.
B. Many small 1 vCPU VMs participating in an OS level clustered application protected by vSphere HA.
C. A few large 8 vCPU VMs per host protected by vSphere Fault Tolerance.
D. Many small l vCPU VMs participating in an OS level clustered application protected by vSphere Fault Tolerance.
Answer: D
Q5. A company has requested assistance with a new cross-site failover design to support business-critical applications.
u2022 It has two sites when are very well-connected, and latency is less than 5ms round trip.
u2022 The customer requires that its applications be restarted even in the event of a total site failure.
u2022 The applications must be kept online even when migrated during maintenance.
u2022 Storage arrays at either site support both synchronous and asynchronous replication. Which two options are accurate application requirements for this scenario? (Choose two.)
A. The design must ensure continuous application uptime even during a total site failure.
B. The design must prioritize application availability.
C. The design must ensure application recoverability at the second site.
D. The applications are latency-sensitive.
Answer: AB
Q6. A company is outsourcing its support operations to an external service provider and plans to complete the project by April 1.
u2022 The external Support engineers must have the ability to power cycle, create, and edit virtual machines settings within their assigned vSphere site.
u2022 The company maintains three vCenter servers in Enhanced Linked Mode that are run as virtual machines in the supported infrastructure.
u2022 The vCenter servers will be supposed by the external service provider.
u2022 Each vCenter server is connected to its own local Platform Services Controller and MSSQL database server.
u2022 The company will provide escalation support and physical access on a per request basis.
u2022 99.9% ESXi host uptime is required in this environment, but no SLA has been specified for the hosted applications.
Drag each statement to its appropriate concept.
Answer:
Q7. A customs has requested a vSphere 6.5 deployment design where ESXi hosts are provisioned with Auto Deploy. The customer requires that certificates can be automatically refreshed and renewed from the vSphere Web Client for ESXi hosts.
Which certificate policy should be configured for vCenter Server?
A. Thumbprint Mode
B. VMware Certificate Authority
C. Custom Certificate Authority
D. Subordinate Certificate Authority
Answer: A
Q8. A customer is using blade servers with only one HBA.
Which two design concepts apply to this scenario? (Choose two.)
A. Assumption
B. Risk
C. Constraint
D. Requirement
Answer: B
Q9. Match the business statement to its appropriate concept.
Answer:
Q10. A company is in the process of deploying a modern video-streaming application.
u2022 The application is able to scale (expand and collapse) its steaming nodes in the form of CentOS 7.x 64bit virtual machines, based on demand.
u2022 This IO-Intensive application has a high CPU demand and generates a significant number of disk operations (IOPS).
u2022 To host the application, the company decided to implement a brand-new VMware cluster with vSphere 6.x
u2022 The company would like a significant reduction in CPU utilization as well as a possible increase in throughput.
Which virtual disk adapter should be recommended for the company's physical design?
A. LSI Logic Parallel
B. VMware Paravirtual
C. BusLogic Parallel
D. LSI Logic SAS
Answer: A
P.S. Easily pass 3V0-624 Exam with Examcollectionplus Printable Dumps & pdf vce, Try Free: https://www.examcollectionplus.net/vce-3V0-624/ ( New Questions)