DEE-1421 Premium Bundle

DEE-1421 Premium Bundle

Expert - Isilon Solutions Certification Exam

4.5 
(50955 ratings)
0 QuestionsPractice Tests
0 PDFPrint version
September 29, 2024Last update

EMC DEE-1421 Free Practice Questions

Your success in EMC DEE-1421 is our sole target and we develop all our DEE-1421 braindumps in a way that facilitates the attainment of this target. Not only is our DEE-1421 study material the best you can find, it is also the most detailed and the most updated. DEE-1421 Practice Exams for EMC EMC Other Exam DEE-1421 are written to the highest standards of technical accuracy.

Online EMC DEE-1421 free dumps demo Below:

NEW QUESTION 1
An IT team is implementingadisaster recovery solution. A Dell EMC Isilon cluster will replace production data from ma existing primary cluster to a planned secondary cluster. The primary cluster is licensed for SmartLock Enterprise whereas the secondary cluster is not.
A Smartlock enterprise type directory on the primary cluster o planned tor replication SynelQ is used to replicate the data. What is a key considerationwhen replicatingme WORM domain?

  • A. Secondary cluster must be licensed tor Smartlock Enterprise
  • B. Files on the primary cluster cannot be committed lo a WORM stale
  • C. A fallback will cause a second copy ofme data on the primary cluster
  • D. Retention dates and commit status are lost on the target directory

Answer: D

NEW QUESTION 2
A Microsoft Windows administratorhas an environment that includes a 4-node Dell EMC Isilon H500 cluster with one subnetand two pools. The administratorwill use SMBv3in all their clients. One pools for production using 10gigo-i and 10gige-2 ports from each node. The other pool is management using rngmt-1 from each node.
One of the concerns is the network throughput and how the administrator can get more than 10GbE throughput on the production pool on each node.Which recommendation should I provided''

  • A. Use LACP active/passive on the 10gige ports from each node to gel more than 10GbE throughput
  • B. Enable SMBv3 multichannel functionality to get more than 10GbE throughput
  • C. Use LACP active/passive on the 10gige ports from each node to get more than 10GbE throughput
  • D. Enable both SM8v3 multichannel functionality and LACP to get into than 10GbE throughput

Answer: B

NEW QUESTION 3
A company’s HPC environment is using Dell EMC Isilon Gen 6 nodes. They have additional throughput requirements and have asked for your recommendations. The environment consists of two subnets:
DEE-1421 dumps exhibit Mgmt-subnet: 1x1-GigE interface in the “mgmt-pool” for management traffic on a VLAN-tagged management network in an Isilon default System Access zone.
DEE-1421 dumps exhibit Data-subnet: 2x10-GigE aggregated interfaces in the “data-pool” for data traffic on a VLAN-tagged data network in an Isilon user-defined data Access Zone
Which recommendation should be provided?

  • A. Remove VLAN tagging from f e network
  • B. Move the data pool into the System Access zone
  • C. Use differentgroupnets for management and data traffic
  • D. Use only one subnet and pool for both the management and data traffic

Answer: C

NEW QUESTION 4
You nave just configured a Dell EMC lsilon cluster. One of the remaining tastes is to enable alert notification. The cluster is on a network segment behind a firewall for security. You have determined which node is the CELOG master and have enabled connectivitybetween it and the ESRS gateway.
Testing shows that alerts were working for several daysbut have suddenly slopped. Which action is required to resolve this issue?

  • A. Edit and enable the Alert Channel for ConnectEMC
  • B. Enable TCP port 443 between all nodes and the ESRS gateway
  • C. Enable TCPport 25 Between all nodes and the SMTP server
  • D. Ensure only the first cluster nodeis in the 'allowed list in Work Channel settings

Answer: A

NEW QUESTION 5
You are assisting a company in planning for a Dell EMC Isilon disaster recoverysites. One ofthe company's concerns is the time that is needed for the initial synchronization between the primary and disaster recovery sites.
What will help address tins concern?

  • A. After creating the policies, use the “assess sync” functionality
  • B. After creating the policies, start the job and observe how much time it takes
  • C. Time cannot be estimated due to many factors such as the cluster workload
  • D. Use a third-party tool to estimate the time based on the date and thebandwidth available

Answer: B

NEW QUESTION 6
A company is adding a 48-node A2000 with 10 TB HDDs for deep archival data to their existing Dell EMC cluster. The existing consists of a 10-node x210 and an 8-node NL410. What is the minimum recommended protection settings for the a200?

  • A. N:3d:1nd
  • B. N+4n
  • C. N+4d1n
  • D. N+4d:2n

Answer: D

NEW QUESTION 7
A company uses the Dell EMC Isilon cluster’s A200 nodes for short-team archiving of digitized film. Historical and trending information shows that the cluster capacity will reach 90% full in 60 days. To avoid the need to purchase additional A200 nodes, the company requires a solution that archives data not accessed for 18 months to a more cost-effective platform. The long-term archive data must be online and accessible. Some performance loss is acceptable.
Which IT strategy provides a long-term solution that meets the requirements?

  • A. Use a CloudPoots policy to move the target date lo an ECS-powered cloud
  • B. Use NDMP to backup to disk using compression and reduplication
  • C. Use SynclQ to replicate me archive to the H600 nodes on the secondary cluster
  • D. Use datareduplication on archived date not accessed within180 days

Answer: B

NEW QUESTION 8
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens.
When displaying a question, you can easily review the related case study by clicking on the “Review Case Study” icon shown below:
DEE-1421 dumps exhibit
Case Study 5– Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes. Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC NetWorker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?

  • A. Add A100 Backup Accelerators and configurefor two-way NDMP
  • B. Change the backup strategy to token-based backups
  • C. Exclude the targets datasets from the backup job
  • D. Create more parallel streams to utilize multi-stream NDMP backups

Answer: A

NEW QUESTION 9
A media company has a Microsoft Windows-based infrastructure and uses Adobe media editing tools to create advertisements for its customers Users from the Media Production department store all types of media ties on a Dell EMC Isilon cluster.
In addition, users from the Support department are not allowed to store MP3 and AVI files to the NAS system. Both the Media Production and Support departments need to access other common data on the cluster. Due to workflow procedures, the media files are stored on the same path on me Isilon cluster.
The company wants toKnow which ision features are available and can restrict the Support department users from writing certain media file types onto the Isilon cluster. Which recommendation should be provided/

  • A. Create a single SMB share for bothdepartmentsUse the share security settings end Windows NTFS settings to restrict thetypes
  • B. Create an SMG snare for the Support department and restrict the Media Productiondepartment users from accessing the shareCreate another SMB share for Via Media Production department and apply file Altering
  • C. Create a separate Access zone for each departmentUse Sync 10 to replicate the data and exclude the media files
  • D. Create aSMBsnare for me MediaProduction department and restrict the Support department users from accessing the shareCreole another SMB share for the Support department and apply file filtering

Answer: A

NEW QUESTION 10
A company has a medical application that generates a large number of media files.The file count is well over one billion and is stored on a Dell EMC lsilon 8-node N14I0 Cluster Currently, each node ft connected to me network using two 10GbE concoctions. The Linux-based application does not require high bandwidth; however, it is latency sensitive. Additionally, the Linux hosts are connected to the cluster over NFSv3 .The application generates approximately 10.000 files every 10 minutesfor the past four years, the cluster has been growing at a rate of one additional node per year. The company is running out free ports on their redundant network switches. They want to know what can be done to ensure continuous availability. They do not want to invest in upgrading the network infrastructure. In addition the company needs to reduce the number ol consumed interface ports on the switches.
Which recommendation should be provided?

  • A. Leave the first four nodes of the cluster connected to both network switches and free up the remanding connections
  • B. Leave the fast 10GbE Interfacefrom each node connected to the same network switch and hoe up the remaining connections
  • C. Leave the first node of the cluster connected to both network switches and free up theremainingconnections
  • D. Leave the fast four nodes of the cluster connected to both network switches with LACP and free up the remaining connections

Answer: D

NEW QUESTION 11
A Dell EMC Isilon administrator has a 6-node X400 cluster. As the hardware is approaching end of service life, the administrator has planned for a technical refresh by replacing the 6-node X400 cluster with a 4-node H500 cluster.
The new 4-node H500 is added to the existing cluster and a SmartPools trial license is activated for data migration. The default location for the data and snapshots is changed in the default file pool policy from an X400 node pool to a H500 node pool. The SmartPool job is then run manually.
After the SmartPool job is finished, the X400 node pool still consumes approximately 10% of the storage. What is a possible reason for this issue?

  • A. SyncIQ migration method should have been used
  • B. Manually-managed files and directories still exist
  • C. SmartPools mat license is not sufficient, a W license « required
  • D. SmartPool job finished with error
  • E. Dell EMC Support needs to be contacted

Answer: B

NEW QUESTION 12
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
DEE-1421 dumps exhibit 200 TB of Fibre Channel drives on NetApp ONTAP 7
DEE-1421 dumps exhibit Environment is expected to grow 200 TB over the next three years
In order to remove the encryption key on the SED drives, which steps are required?

  • A. SmartFail the cluster and then remove the drive
  • B. Suspend the cluster and then SmarlFail the drive
  • C. Suspend the node and then remove the drive
  • D. SmartFail and then remove the drive

Answer: C

NEW QUESTION 13
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens.
When displaying a question, you can easily review the related case study by clicking on the “Review Case Study” icon shown below:
DEE-1421 dumps exhibit
Case Study 5– Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC NetWorker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigation, you notice that the backup job targets two paths. This could be the cause of the lengthy backup times.
What advice should be provided to the team?

  • A. Exclude the largest datasets from the backup job
  • B. Add A100 Backup Accelerators and configure for two-way NDMP
  • C. Create more parallel streams to utilize multi-stream NDMP backups.
  • D. Change the backup strategy to token-based backups.

Answer: C

NEW QUESTION 14
A company has a Dell EMC Isilon cluster that will be used for a large amount of client requests. SmartConnect has been configured to help load balance the clients across the cluster. How does SmartConnect help the load balancing?

  • A. Dynamically updating changes to DNS
  • B. Caching lookup requests
  • C. Forwarding DNS requests
  • D. Directing the connections to different nodes

Answer: D

NEW QUESTION 15
A company has a cluster with twosubnets. The first subnet has 1GbE interfaces dedicated for management and the second subnet has 10GG interfaces dedicated for handling all data access. When the cluster started serving the prediction environment. Poor performance was observed while the data is accessed through the data subnet. White troubleshooting the network the administrator discovered that the return traffic is going through the management network.
Which recommended solution will rescue this issue?

  • A. Configure static routes tor both subnets
  • B. Enable source-based touting
  • C. Enable destination based routing with static routes
  • D. Change the gateway priorities

Answer: D

NEW QUESTION 16
Case Study 4
A company is experiencing a noticeable decrease in performance when accessing data on their Dell EMC Isilon cluster. The cluster hosts Microsoft Windows home directories and general purpose file shares. In addition, a file pool policy moves data that has not been modified in six months to an achieve tier. The
administrator wants your assistance in understanding the reason for the slow data access. The number of users accessing the cluster has not changed.
The administrator has shared the following baseline metrics. The outputs were captured from a performance- acceptable time frame.
Trace route shows:
-3 hops between clients and the cluster
-Average latency is 3 ms Iperf shows:
-940 Mb/s average bandwidth
-005 ms average jitter
Netstat on the local network shows:
-05% average re-transmission rate Hostcache list:
-20 ms average roundtrip time across all clients
The administrator shows you the following output from thenetstatcommand:
DEE-1421 dumps exhibit 32366653 data packets (35556615947 bytes)
DEE-1421 dumps exhibit 8010 data packets (9525723 bytes) re-transmitted
Based on the output, what information should be provided to the administrator?

  • A. Re-transmission rates have no impact on performance
  • B. Re transmission rate exceeds recommendations
  • C. Re-transmission rate is in the acceptable range
  • D. Change in the re-transmission rata indicates an issue

Answer: C

NEW QUESTION 17
A company has an 8-node X410 installed as a single Dell EMC Isilon cluster. The company expressed concerns about cluster performance, particularly about NFS being slow. The output shown in the exhibit was presented to the Dell EMC technician.
Based on this output, what is a reason for the cluster performance issue?
DEE-1421 dumps exhibit

  • A. SmartConnect is not properly balancing the connections
  • B. Average NFSv3 write latency is too high
  • C. Too many namespace_read operations against the cluster
  • D. Number of I/O for a single node is too high

Answer: A

NEW QUESTION 18
Case Study 1
A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated. The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user’s home and group directories and for compliance archival purposes required by individual business units.
The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas. The company has a total of 60 AD forests:
DEE-1421 dumps exhibit 1 main domain
DEE-1421 dumps exhibit 55 domains have one-way trust relationships with the main domain
DEE-1421 dumps exhibit An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains.
Users of different AD domains use different FQDN to access their corresponding file services. Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet. The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas.
How many tenant Access zones will be required?

  • A. 1
  • B. 55
  • C. 59
  • D. 60

Answer: C

NEW QUESTION 19
You are working with a company lo migratefrom a Microsoft Windows file erver to a Dell EMC Isilon cluster using the account 'admin 1" in the 'Domain Admin* group. When opening a directory, you receive an error message stating 'permission denied* You check me permissions and see that Domain Users are denied. Domain Admin has Full Control, and adrmn1has read permission
Why is the access denied?

  • A. Deny ACE entry is listed first
  • B. admin1 is a member of the Domain Admin group
  • C. adrmn1is not the owner of the directory
  • D. admin 1 only has read permission

Answer: D

NEW QUESTION 20
A company g planning to add eight additional nodes to their existing 4-node Dell EMC Isiloncluster. Ifthe administrator plans to add all eight nodes at the same time without causing any outage, what s me result of Hits action?

  • A. OneFS will not proceed with the addition
  • B. All nodes will be added withouterrors
  • C. Quorum will be lost
  • D. All nodes will be added with errors

Answer: B

NEW QUESTION 21
......

100% Valid and Newest Version DEE-1421 Questions & Answers shared by Downloadfreepdf.net, Get Full Dumps HERE: https://www.downloadfreepdf.net/DEE-1421-pdf-download.html (New 60 Q&As)


START DEE-1421 EXAM