Q1. A customer needs to monitor their database volumes to make sure the storage capacity does NOT exceed the desired limits.
What should the engineer do to automate this monitoring for the database volumes?
A. create an automated disk class report
B. create alert monitoring via charting tab
C. create a Threshold Query
D. create a Threshold Definition
Answer: D
Explanation
Referencehttps://davidbraasch.files.wordpress.com/2012/12/680-017-017.pdf
Q2. The administrator notices that some disks show as down intermittently. The disks are all in the same enclosure. What is the problem?
A. Each disk drive must be replaced.
B. The enclosure is powered off.
C. The SAS cable is NOT fully seated.
D. The Disk folder is NOT properly configured.
Answer: D
Q3. A customer has mapped a volume to a ESX server using two 8 Gb Fibre Channel (FC) paths. The customer needs the traffic to split equally across the two FC paths.
Which ESX Multi-pathing policy should be used?
A. Least Queue Depth
B. Most Recently Used (MRU)
C. Round Robin
D. Fixed
Answer: C
Q4. A deployment technician needs to install a dual-controller Storage Center with two Fibre Channel (FC) fabrics. The site will run in Legacy mode.
What is the correct front-end cabling?
A. option A
B. option B
C. option C
D. option D
Answer: D
Q5. An engineer is configuring a storage array in a mixed environment of 10 Gb iSCSI and 16 Gb Fibre Channel. The 10 Gb iSCSI network consists of two separate VLANs and is used for server connectivity. The 16 Gb Fibre Channel network consists of a single fabric and is used to provide high-speed replication connectivity to a secondary storage array for Synchronous Live Volume with Auto Failover.
How many fault domains must the engineer configure on the storage array for each network?
A. One fault domain for iSCSI and two fault domains for Fibre Channel
B. One fault domain for Fibre Channel and one fault domain for iSCSI
C. Two fault domains for iSCSI and one fault domain for Fibre Channel
D. Two fault domains for Fibre Channel and two fault domains for iSCSI
Answer: C
Q6. A customer plans to use an SC8000 unit for long-term storage of CCTV security video recordings. Thus system consists of 84 – 4TB 7k disks. The customer does not plan to take any replays on the system.
Which setup should be recommended to meet the customer’s requirements?
A. Tier Redundancy: Single RedundantData Page size: 2 MB
B. Tier Redundancy: Single RedundantData Page size: 4 MB
C. Tier Redundancy: Dual RedundantData Page size: 512 KB
D. Tier Redundancy: Dual RedundantData Page size: 4 MB
Answer: D
Q7. An engineer has installed an SC4020 with four FC ports in each controller. This is a dual-fabric installation with four FC connections in each server. The servers use the OS built-in multi-pathing capabilities.
Which two configurations will cause the controller failover to fail? (Choose two.)
A. Too many volumes are mapped to the server from one controller.
B. The switch zoning is incorrectly configured.
C. The server HBA timeouts are set incorrectly.
D. The multi-pathing software is incorrectly configured.
Answer: C D
Q8. Which two of the following actions are required to successfully update Storage Center OS using the Storage Center Update Utility? (Choose two.)
A. Check the box in Edit Storage Center Settings to enable Storage Center Update Utility.
B. Send a SupportAssist so that a SCOS Pre-Upgrade check can be done first.
C. Pause Live Volume replications prior to starting the Storage Center update process while using this utility.
D. Disable SupportAssist to allow the Storage Center Update Utility to communicate with the Storage Center.
E. Apply a license to the Storage Center to use the Storage Center Update Utility.
Answer: A C
Explanation
Referencehttp://topics-cdn.dell.com/pdf/storage-sc2000_Administrator%20Guide3_en-us.pdf
Q9. Which two steps should the engineer take prior to racking any equipment? (Choose two.)
A. remove batteries from controllers to prevent risk of electric shock
B. remove any jewelry ormetal objects from the engineer’s body
C. remove the disk drives from inside the shipped enclosures
D. apply an ESD wrist or ankle strap to avoid damage to parts
Answer: B D
Q10. An engineer updates the SCOS version from 6.5.x to 6.6.x on an SC4020 via ISO. The engineer uses the following credentials: admin / admin. The engineer calls Dell Support for final health checks and is informed that a newer SCOS 6.6.x version is available. The engineer tries to perform another ISO update to the newest SCOS 6.6.x version. The engineer is unable to log back in to the BMC interface to start the ISO update.
What should the engineer do to update the newest SCOS version via ISO?
A. use the login credentials root/ calvin in SCOS 6.6.x
B. update Java to version 8 to use the updated BMC interface
C. downgrade Java to version 7 from version 8
D. request Dell Support to reset the expired admin password
Answer: A
Q11. Refer to the exhibit.
An engineer needs to correctly configure the fault domain on the Storage Array for the dual-fabric Fibre Channel environment shown. Full connectivity and failover from the storage array configured in legacy port mode for the servers in this environment are required.
Which fault domain configuration meets the requirements?
A. A fault domain that contains P4, P3, P2, and P1; and a fault domain that contains R4, R3, R2, and R1
B. A fault domain that contains P4, R4, P3, and R3; and a fault domain that contains P2, R2, P1, and R1
C. A fault domain that contains P4 and R4, a fault domain that contains P3 and R3, a fault domain that contains P2 and R2, and a fault domain that contains P1 and R1
D. A fault domain that contains P4 and P3, a fault domain that contains R4 and R3, a faultdomain that contains P1 and P2, and a fault domain that contains R1 and R2
Answer: B
Q12. A customer has multiple Storage Centers at their main site and a DR system at a remote site. A particularly important volume requires High Availability protection. An outage on one system at the main location must NOT cause data to be inaccessible. Disaster Recovery protection is also required to protect data even if the entire main site goes down.
Which technology best meets these requirements?
A. Asynchronous Replication
B. LiveVolume Managed Replication
C. Fluid Data Architecture
D. Synchronous Replication
Answer: B
Q13. An engineer has several servers connected to the Storage Center through two FC fabrics. The Storage Center runs in Virtual Ports mode. The engineer needs to create zones based on World Wide Names (WWN).
Which WWNs from the Storage Center need to be included in the zone with the server WWN?
A. only the Primary WWNs
B. only the Virtual WWNs
C. both the Primary and Reserve WWNs
D. both the Virtual and Physical WWNs
Answer: B
Q14. A Storage Administrator wants to do a Storage Center OS update to SCOS version 6.7.5. The Storage Center is currently at SCOS version 6.5.30. The Storage Center is at a secure facility and does NOT allow connectivity to any network outside the facility. The Storage Administrator is trying to use the Storage Center Update Utility to accomplish this task, but has been unsuccessful in doing so.
Why has the Storage Administrator been unsuccessful?
A. The Storage Center hasNOTpassed Pre-Upgrade checks and is blocking the update from occurring.
B. The secure facility is NOTallowing the StorageAdministrator’s laptop to connect to the Storage Center across the network.
C. The Storage Center isNOTlicensed to use the Storage Center Update Utility.
D. The Storage Center isNOTat the minimum required SCOS version to use the utility.
Answer: D
Q15. An engineer needs to install an SC8000 with four FC ports in each controller and two FC switches set up in a dual fabric. Each controller also has two 10 Gb iSCSI ports. All iSCSI ports are connected to an ethernet switch. The system uses virtual ports.
How many fault domains are required?
A. 3
B. 5
C. 4
D. 2
Answer: C
Q16. An engineer is investigating network congestion on the iSCSI network and finds pause frames are rapidly incrementing on all host and ISL switch ports, but NOT on the array switch ports. All switch ports are configured for both send and receive flow control.
What should the engineer conclude?
A. Flow control is disabled on the array.
B. High TCP/IP retransmits are causing pause frames.
C. The ISL bandwidth is exceeded.
D. Spanning tree convergence is pausing IO.
Answer: B
Q17. Refer to the exhibit.
An engineer has almost finished the setup wizard when the screen appears as shown. What are two reasons that FC should remain in Legacy mode? (Choose two.)
A. The customer has servers that run an older version of AIX.
B. The customer has an FC switch that does NOT support NPIV.
C. The customer needs to replicate some volumes to an olderSC40.
D. The environment only has one fabric/network.
Answer: A B