NS0-520 Premium Bundle

NS0-520 Premium Bundle

NetApp Certified Implementation Engineer - SAN. ONTAP Certification Exam

4.5 
(56445 ratings)
234 QuestionsPractice Tests
234 PDFPrint version
September 29, 2024Last update

Network-Appliance NS0-520 Free Practice Questions

Cause all that matters here is passing the Network-Appliance NS0-520 exam. Cause all that you need is a high score of NS0-520 NetApp Certified Implementation Engineer - SAN. ONTAP exam. The only one thing you need to do is downloading Certleader NS0-520 exam study guides now. We will not let you down with our money-back guarantee.

Also have NS0-520 free dumps questions for you:

NEW QUESTION 1

A customer has an FC host that needs to be attached to the NetApp AFF A700 dual controller storage cluster. To accomplish this task, which three steps should the customer perform? (Choose three.)

  • A. Configure the FCP service for the node that has the LUN that is being accessed.
  • B. Confirm that the FC HBA driver and firmware is supported according to the Interoperability Matrix Tool (IMT)
  • C. Configure portsets to support the availability of multiple paths.
  • D. Configure an igroup with the WWPN from the host initiator for LUN access.
  • E. Confirm that the switch firmware is supported according to the Interoperability Matrix Tool (IMT).

Answer: CDE

NEW QUESTION 2

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, what is the total amount of space that is guaranteed for the LUNs in the
/vo1/vo1_sanlunsiprod_03 volume?

  • A. 0 GB
  • B. 300 GB
  • C. 600 GB
  • D. 2600 GB

Answer: A

NEW QUESTION 3

Exhibit.
NS0-520 dumps exhibit
A customer is testing a dual-fabric FC SAN configuration as shown in the exhibit and the zones are implemented on the switches shown below.
NS0-520 dumps exhibit
If all the nodes are in the SLM reporting nodes list, hoe many path per LUN should the customer expect when simulating an FC SFP failure by bringing LIF_3 offline?

  • A. 15 paths
  • B. 3 paths
  • C. 4 paths
  • D. 7 paths

Answer: D

NEW QUESTION 4

Click the Exhibit button.
NS0-520 dumps exhibit
You are implementing an ONTAP 9.5 AFF A300 SAN cluster with the NVMe, FC, and FCoE protocols. Referring to the exhibit, which three protocols and physical port pairs are supported? (Choose three.)

  • A. NVMe on ports 2a/2b
  • B. FC on ports 2a/2b
  • C. NVMe on ports 0e/0f
  • D. FCoE on ports 0e/0f
  • E. FC on ports 0e/0f

Answer: BCD

NEW QUESTION 5

You are configuring a VMware sphere host for FC access to a Netapp ONTAP cluster. In this scenario, which two tasks does Netapp recommend performing on the Vsphere host? (choose two)

  • A. Set the queue depth on the host to 8
  • B. Update the HBA driver
  • C. Zone the host by using the host WWNNs
  • D. Use the Netapp Virtual Storage Console to configure the host settings

Answer: BD

Explanation:
Zoning the host using WWNNs is not recommended. Netapp always recommends to use WWPN to zone correctly.
We can not stablish a queue depth value because we don't have the amount of ports and hosts to calculate the recommended queue depth
Installing VSC and updating the HBA driver are best practices recommended by Netapp
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=/com.netapp.doc.exp-iscsi-esx-cpg/GUID-C751F905-0 https://docs.netapp.com/ontap-9/topic/com.netapp.doc.exp-fc-esx-cpg/FC express configuration for%
(page 7)

NEW QUESTION 6

You create a new iSCSI SVM and secure iSCSI sessions by using both Challenge-Handshake Authentication Protocol (CHAP) and iSCSI Access Control Lists (ACL).
In this scenario, in which two ways are you securing your iSCSI implementation? (Choose two.)

  • A. CHAP creates a hash value for the username and shared secret.
  • B. iSCSI ACLs are applied to the initiator configuration to provide an IP address of the targets.
  • C. CHAP encrypts all iSCSI session I/O.
  • D. iSCSI ACLs are applied to the target configuration to provide an IP address of the initiators.

Answer: AD

NEW QUESTION 7

Which resource would you use to verify whether a specific SAN configuration is supported by NetApp?

  • A. SAN Configuration Guide
  • B. Hardware Universe (HWU)
  • C. Active IQ
  • D. Interoperability Matrix Tool (IMT)

Answer: A

Explanation:
Reference: https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/SAN configuration.pdf

NEW QUESTION 8

Which data collection tool would be used for obtaining detailed information about hosts that are attached to ONTAP storage?

  • A. Upgrade Advisor
  • B. OneCollect
  • C. Brocade Network Advisor
  • D. Conflg Advisor

Answer: B

NEW QUESTION 9

An administrator is migrating from a third-party's SAN to a newly purchased FAS9000. The administrator decides to use the NetApp Foreign LUN Import (FL1) process.
What must the administrator do for this process to work properly?

  • A. Create multiple igroups for the Initiator ports.
  • B. Create six distinct zones that include specific ports within each zone.
  • C. Zone target ports of source storage with initiator ports of destination storage.
  • D. Make the destination LUN larger than the foreign LUN.

Answer: C

NEW QUESTION 10

You created a LUN in a new volume on your Netapp ONTAP cluster. You enabled the default snapshot schedule and enabled snapshot autodelete on the volume. In this scenario, in which three situations
does the snapshot autodelete feature automatically delete snapshot copies in the volume? (choose three)

  • A. The snapshot reserve space is nearly full
  • B. The LUN is nearly full
  • C. The overwrite reserve space is full
  • D. The volume is nearly full
  • E. The aggregate is nearly full

Answer: ACD

Explanation:
Depending on what is selected in the "Trigger" option, Snapshot Autodelete will automatically delete a snapshot when, either the volume space utilized, or the snapshot reserve reaches a threshold capacity
specified below.
Automatic deletion of Snapshot copies from flexible volumes Data ONTAP can automatically delete one or more Snapshot copies on the volume, provided the Data ONTAP Snapshot copy autodeletion
policy is enabled and set to trigger when the overwrite reserve is nearly full on the volume. You can find more information on this link:
https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/How_to_use_Snapsh
https://library.netapp.com/ecmdocs/ECMP1217281/html/GUID-98FB8EC4-F3AE-4D25-AF44-E3200AFEB1A

NEW QUESTION 11

What is a SAN best practice when initially configuring a Linux FC boot LUN?

  • A. Install the Host Utilities in the guest Linux OS.
  • B. Map the WWPN of the target.
  • C. Disable the HBA port with the host’s BIOS.
  • D. Configure multipath to the LUN.

Answer: B

Explanation:
Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1217221

NEW QUESTION 12

A customer is expanding an ONTAP 9.4 switchless 2-node FAS2750 cluster. Two AFF A220 nodes will be added to the cluster.
In addition to the cluster nodes, what else is required to perform the cluster expansion?

  • A. Additional management switches are required.
  • B. An upgrade to ONTAP 9.5 is required.
  • C. Cluster switches are required.
  • D. Additional DS224C shelves are needed.

Answer: A

NEW QUESTION 13

Exhibit.
NS0-520 dumps exhibit
You want to map a LUN to a server.
To which SAN object is the highlighted value in the exhibit added?

  • A. LUN
  • B. fabric zone
  • C. FlexClone
  • D. igroup

Answer: D

NEW QUESTION 14

You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage.
What are three reasons for this problem? (Choose three.)

  • A. The protocol has not been enabled on the NetApp cluster.
  • B. You need to add the IQN of the Windows host to the newly created LUN.
  • C. The IQN of the Windows host is not included in the igroup for the new LUN.
  • D. The wrong igroup has been associated with the new LUN.
  • E. The volume has not been enabled for iSCSI access.

Answer: ABD

NEW QUESTION 15

An administrator has an AFF A200 cluster at their primary site that is used for FC connectivity to servers. For disaster recovery purposes they want to start replicating their data to another AFF A3Q0 cluster In a secondary location. The AFF A300 is In a site that has no FC or FCoE capable switches, and is currently only used for CIFS data. A cluster peering relationship already exists between the two clusters.
Which three additional actions are needed for the data to be ready for access from hosts at the secondary site? (Choose three.)

  • A. Create zones with the appropriate initiators and targets for the secondary site.
  • B. Enable the iSCSI service on the SVM at the secondary site.
  • C. Replicate the data from the primary site to the secondary site with SnapMirror.
  • D. Create new iSCSI igroups for LUN mapping.
  • E. Enable the iSCSI service on the SVM at the primary site.

Answer: BCD

NEW QUESTION 16

Changes to your organization requires access to an SVM be given to a group of individuals. Your company uses Active Directory as a method of access control. You decide to use the security login create - vserver engCluster -user-or-group-name CORPAdmins -application ssh -authmethod domain -role vsadmin command.
In this scenario, which access rights will this command grant?

  • A. read only rights to the SVM engCluster for Active Directory group CORP
  • B. vsadmin rights to the SVM engCluster for Active Directory group CORPAdmins
  • C. vsadmin rights to the SVM CORP for Active Directory group CORPAdmins
  • D. vsadmin rights to the SVM engCluster for Active Directory group CORP

Answer: B

NEW QUESTION 17
......

P.S. Easily pass NS0-520 Exam with 234 Q&As Surepassexam Dumps & pdf Version, Welcome to Download the Newest Surepassexam NS0-520 Dumps: https://www.surepassexam.com/NS0-520-exam-dumps.html (234 New Questions)


START NS0-520 EXAM