NS0-520 Premium Bundle

NS0-520 Premium Bundle

NetApp Certified Implementation Engineer - SAN. ONTAP Certification Exam

4.5 
(56460 ratings)
234 QuestionsPractice Tests
234 PDFPrint version
September 29, 2024Last update

Network-Appliance NS0-520 Free Practice Questions

Cause all that matters here is passing the Network-Appliance NS0-520 exam. Cause all that you need is a high score of NS0-520 NetApp Certified Implementation Engineer - SAN. ONTAP exam. The only one thing you need to do is downloading Passleader NS0-520 exam study guides now. We will not let you down with our money-back guarantee.

Also have NS0-520 free dumps questions for you:

NEW QUESTION 1

An administrator is configuring their existing Ethernet network switches to provide ISCSI LUNs to several servers. The network switches are also used for other traffic from various hosts. In this scenario,
which statement is true?

  • A. Increase the ratio of access ports to trunk ports to 2:1
  • B. Configure the MTU size to be larger on the switch and storage than on the host.
  • C. Use multiple VLANs to isolate traffic from other network traffic
  • D. Netapp recommends using the same LIFs for NFS and ISCSI traffic

Answer: C

Explanation:
VLANs offer specific benefits, such as increased security and improved network reliability that you might want to leverage in iSCSI.
You can find more information on this link:
https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/SAN configuration.pdf (page 5)

NEW QUESTION 2

Your customer asks you to configure a newly installed FAS8300 for an FC host connection. Referring to the exhibit, which step accomplishes this task?
NS0-520 dumps exhibit

  • A. Configure the ports 0e and 0f as a mode of CNA
  • B. Configure the ports 0e and 0f as type of target
  • C. Configure the ports 0e and 0f as status admin up
  • D. Configure the ports 0e and 0f as status admin down

Answer: B

Explanation:
To change the port type from initiator to target you need to take the port offline The ports need to be on target mode to present LUNs to the hosts.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=/com.netapp.doc.dot-cm-sanag/GUID-193C6818-EDB

NEW QUESTION 3

A storage administrator created a LUN using two ports on a storage system. Later, additional LUNs were added to the same node as the original LUN. After a while, the performance of the original LUN dropped beyond an acceptable level.
What would you advise to remedy the Issue?

  • A. Add an additional switch between the hosts and cluster.
  • B. Add new LIFs on unused ports.
  • C. Add new LIFs on the used ports.
  • D. Reduce the queue depth on the used ports.

Answer: B

NEW QUESTION 4

Which four FC fabric topologies does NetApp support? (Choose four.)

  • A. four FC switches with multiple Inter-Switch Links (ISLs) between each pair of switches
  • B. ten FC switches per fabric, daisy chained with a single ISL between switches
  • C. four FC switches with multiple ISLs between ALL switches
  • D. eight FC switches with no more than a single ISL between switches in a cascade topology
  • E. dual FC switches with no ISLs
  • F. a single FC switch
  • G. a switched fabric that has 65537 ports

Answer: ACEF

NEW QUESTION 5

A customer has multiple host applications that require FC block storage. You need to gather and validate the customer’s requirements for a supported NetApp solution.
Which two tools would be used to accomplish this task? (Choose two.)

  • A. Interoperability Matrix Tool (IMT)
  • B. OneCollect
  • C. Config Advisor
  • D. Hardware Universe (HWU)

Answer: AD

Explanation:
Reference: https://www.netapp.com/us/technology/interop.aspx

NEW QUESTION 6

A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth is set to 64. The FC hosts are now experiencing random connectivity issues.
In this scenario, what would be the reason for the disconnects?

  • A. The FC host has a lower queue depth.
  • B. According to the IMT, unsupported HBA firmware is in use.
  • C. All of the hosts are part of the same cluster.
  • D. The queue depth is not consistent across the cluster.

Answer: A

NEW QUESTION 7

You are designing a new 4-node AFF A400 SAN cluster with 20 ISCSI hosts. Each AFF A400 node will have four data LIFs. Each ISCSI host needs to access every LUN over two LIFs per node on every
SAN node.
In this scenario, which Netapp SAN feature enable this connectivity?

  • A. Port sets
  • B. HBA queue depth
  • C. Selective LUN mapping
  • D. Asymmetric namespace

Answer: A

Explanation:
SLM will choose 4 LIFs per node, being 8 LIF total (owner and HA partner), enabling portsets will help to limit the ports per node... that way we can stablish only 2 LIF per node.
Creating port sets and binding igroups to port sets
In addition to using Selective LUN Map (SLM), you can create a port set and bind the port set to an igroup to further limit which LIFs can be used by an initiator to access a LUN. If you do not bind a port set
to an igroup, then all of the initiators in the igroup can access mapped LUNs through all of the LIFs on the node owning the LUN and the owning node's HA partner.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=/com.netapp.doc.dot-cm-sanag/GUID-5CC27202-A43

NEW QUESTION 8

On your ONTAP 9.5 cluster, you need to set up the onboard key manager with hardware-based security and volume encryption.
Which two licenses are required in this situation? (Choose two.)

  • A. FDE
  • B. TPM
  • C. VE
  • D. RSA

Answer: CD

NEW QUESTION 9

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, which type of zoning should be used?

  • A. a WWPN with a single initiator and multiple targets
  • B. a WWPN with a single initiator and a single target
  • C. a WWNN with a single initiator and multiple targets
  • D. a WWNN with a single Initiator and a single target

Answer: B

NEW QUESTION 10

You are planning to install a new AFF All SAN Array A250 system and want to use persistent ports. In this
scenario, what should be identical within the HA pair?

  • A. FCP port MTU size
  • B. FCP Port
  • C. FCP port names
  • D. FCP port LIF WWNN-based zoning

Answer: C

Explanation:
Graphical user interface, text, application, email Description automatically generated
NS0-520 dumps exhibit
You can find more information on this link: https://www.netapp.com/pdf.html?item=/media/10379-tr4515.pdf&v=20217121554 (11)

NEW QUESTION 11

Which NetApp tool provides a detailed inventory of SAN components?

  • A. Active IQ OneCollect
  • B. Interoperabilty Matrix Tool
  • C. Active IQ config advisor
  • D. Hardware Universe

Answer: A

Explanation:
ActiveIQ OneCollect is a tool from NetApp that will create an inventory of your environment that will include hosts, switches and storage and validate it against the IMT (Interoperability Matrix Tool).

NEW QUESTION 12

Which option needs to be set on a LUN to guarantee that it cannot be affected by other LUNs in the volume?

  • A. Volume Guarantee
  • B. Volume Space Reserved
  • C. LUN Reservation Disabled
  • D. LUN Reservation Enabled

Answer: D

NEW QUESTION 13

You are provisioning storage to an ESX host that uses iSCSI.
According to NetApp best practice, which three actions accomplish this task? (Choose three.)

  • A. Enable the iSCSI service.
  • B. Bind the iSCSI ports to the software iSCSI adapter.
  • C. Install Virtual Storage Console (VSC) for VMware.
  • D. Enable BGP on the switch.
  • E. Configure MTU 1500 on the switch.

Answer: BCE

NEW QUESTION 14

You want to access and mount a Linux L.UN using only iSCSl. In the past, the LUN ha;; been accessed using FC. What must you do to accomplish this task?

  • A. Change the LUN protocol type to (SCSI.
  • B. Create a new iSCSI igrou
  • C. and change the LUN mapping from the original to the new igroup.
  • D. Create a new iSCSI Igroup and map the LUN to both the new and existing FC igroup.
  • E. Add an iSCSI protocol type to the existing igroup so that the LUN can be accessed by both FC and iSCSI hosts.

Answer: B

NEW QUESTION 15

An administrator is adding new hosts to a vSphere cluster. The cluster uses the FC protocol to connect to a NetApp cluster. The administrator wants to configure the multipathing for the ESXi host.
Which NetApp tool should be used to accomplish this task?

  • A. OnCommand System Manager (OCSM)
  • B. Host Utilities
  • C. SnapCenter plug-in
  • D. NetApp Virtual Storage Console (VSC)

Answer: D

Explanation:
Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1547465

NEW QUESTION 16

NS0-520 dumps exhibit
Referring to the exhibit, which two pairs of ports are currently configurable as FC SAN LIFs? (Choose two.)

  • A. 01b, 0h
  • B. 01a, 0g
  • C. 01a, 0h
  • D. 01b, 0g

Answer: D

NEW QUESTION 17
......

Recommend!! Get the Full NS0-520 dumps in VCE and PDF From Allfreedumps.com, Welcome to Download: https://www.allfreedumps.com/NS0-520-dumps.html (New 234 Q&As Version)


START NS0-520 EXAM