NS0-592 Premium Bundle

NS0-592 Premium Bundle

NetApp Certified Support Engineer - ONTAP Specialist Certification Exam

4.5 
(55905 ratings)
65 QuestionsPractice Tests
65 PDFPrint version
September 29, 2024Last update

Network-Appliance NS0-592 Free Practice Questions

We provide real NS0-592 exam questions and answers braindumps in two formats. Download PDF & Practice Tests. Pass Network-Appliance NS0-592 Exam quickly & easily. The NS0-592 PDF type is available for reading and printing. You can print more and practice many times. With the help of our Network-Appliance NS0-592 dumps pdf and vce product and material, you can easily pass the NS0-592 exam.

Also have NS0-592 free dumps questions for you:

NEW QUESTION 1
A customer called you after a failure in their Microsoft Hyper-V environment on the “SVM1” SVM. The customer wants to enable nondisruptive operations (NDO) to prevent future failures.
In this scenario, which two actions must be performed? (Choose two.)

  • A. Verify that the continuously-available option is set on the CIFS share.
  • B. Verify that SMB2 is enabled.
  • C. Verify that SMB3 is enabled.
  • D. Verify that the branchcache option is set on the CIFS share.

Answer: AB

NEW QUESTION 2
Click the exhibit button.
NS0-592 dumps exhibit
A customer’s system reported several errors. There was no disruption, but the customer is concerned about the system’s health.
Referring to the exhibit, which statement is true?

  • A. One of the switches has failed.
  • B. One of the IOM modules on shelf 20 has failed.
  • C. Storage redundancy is degraded.
  • D. Port 1D on the system has failed.

Answer: C

NEW QUESTION 3
The root aggregate on your single-node ONTAP cluster failed. You have the configuration backups saved on your FTP server?
In this scenario, which two steps are part of the recovery procedure? (Choose two.)

  • A. Perform a Netboot using the configuration backup.
  • B. Create a new aggregate and set its ha_policy option to sfo.
  • C. Boot into maintenance mode.
  • D. Create a new root aggregate and set its ha_policy option to cfo.

Answer: CD

NEW QUESTION 4
Click the exhibit button.
NS0-592 dumps exhibit
NS0-592 dumps exhibit
A customer reports that storage latency has recently increased substantially. No changes have been introduced, and the traffic did not change.
Referring to the output shown in the exhibit, which corrective step should be taken?

  • A. Add more spindles.
  • B. Throttle the client traffic.
  • C. Perform the volume reallocation.
  • D. Move some volumes off the affected aggregate.

Answer: B

NEW QUESTION 5
A reboot was performed by a watchdog reset on the node. In this scenario, which statement is true?

  • A. The service processor no longer responds.
  • B. In case of an L1 watchdog event, determine whether a panic message was recorded.
  • C. In case of an L2 watchdog event, determine whether a core was dumped.
  • D. The wafl_check command should be executed.

Answer: A

NEW QUESTION 6
Which statement is correct about the wafliron command?

  • A. The wafliron command is used to correct parity inconsistencies.
  • B. The wafliron command is used to correct inconsistent WAFL metadata.
  • C. The wafliron command is used to correct WAFL i2p inconsistencies.
  • D. The wafliron command is used to correct inconsistent user data blocks.

Answer: B

NEW QUESTION 7
A new cluster running ONTAP 9.5 has just been installed and you want to create a FlexGroup volume. Which action will accomplish this task?

  • A. Use the storage pool create command.
  • B. Use the volume create command.
  • C. Use the Deploy utility to provision the FlexGroup volume.
  • D. Use the volume size command.

Answer: A

NEW QUESTION 8
Click the exhibit button.
NS0-592 dumps exhibit
NS0-592 dumps exhibit
NS0-592 dumps exhibit
NS0-592 dumps exhibit
You are troubleshooting a system in which the customer reports that aggregates on Stack 6c/12b are having slow response tomes from system NETAPP1CLUS-02.
Referring to the exhibit, which two statements are correct? (Choose two.)

  • A. The aggregates have only one PHY running at six gigabits per second on 6c.
  • B. PHY 2 is running at six gigabits per second; on system NETAPP1CLUS-02, reseat IOM6 Module A on Shelf 10.
  • C. The shelf module firmware is downrev; on system NETAPP1CLUS-02, replace IOM6 Module A on Shelf 10.
  • D. The aggregates have only PHY at six gigabits per second on 12b.

Answer: AC

NEW QUESTION 9
When you issue a volume clone create command, which entity in WAFL is copied?

  • A. the vol_info block
  • B. the buftree
  • C. the data block
  • D. the inode file

Answer: D

NEW QUESTION 10
A customer reports that a takeover has been disabled on an HA pair. What would be a cause for this to happen?

  • A. The HA interconnect is not functioning properly.
  • B. There is a disk running too hot.
  • C. The interface for the hardware assist has become unavailable.
  • D. The cluster network is not functioning properly.

Answer: A

NEW QUESTION 11
Your customer added a new DS2246 shelf to an existing stack on their FAS8060A system. The customer then noticed that the new shelf’s disks appear with the shelf serial number instead of the shelf ID in the sysconfig -r command output.
What is the reason for this problem?

  • A. The SAS is cabled incorrectly.
  • B. There is failed IOM module in the new shelf.
  • C. The ACP is cabled incorrectly.
  • D. The new shelf has the same ID as another shelf.

Answer: A

NEW QUESTION 12
Click the exhibit button.
NS0-592 dumps exhibit
The storage administrator for the company example.com is attempting to join an SVM to their Active Directory as SVM1. The computer account must also be joined to the Secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit. What is the reason for this error?

  • A. The requested OU Secure does not exist in the Active Directory and must be created by the Active Directory administrator.
  • B. The requested OU Secure has incorrect principal and errored with KRB5KDC_ERR_S_PRINCIPAL_UNKNOWN.
  • C. The administrator account password used in vserver cifs create was not entered correctly.
  • D. The syntax is incorrect; it should be vserver cifs create -cifs-server svm1 -domain example.com -ou ou=Secure, dc=example, dc=com.

Answer: B

NEW QUESTION 13
Click the exhibit button.
NS0-592 dumps exhibit
When you log in to a node, a warning is displayed as shown in the exhibit. Which statement is correct in this scenario?

  • A. The node root volume was moved to a new aggregate.
  • B. The partner still hosts the CFO aggregate for the node.
  • C. One or more RDB db files are damaged due to an internal software error.
  • D. The node cannot communicate with the rest of the nodes in the cluster.

Answer: D

NEW QUESTION 14
You want to determine which SMB versions that a CIFS server can use when communicating with external servers.
Which two CIFS server settings should be reviewed to accomplish this task? (Choose two.)

  • A. smb2-enabled
  • B. smb1-enabled-for-dc-connections
  • C. smb2-enabled-for-dc-conections
  • D. smb1-enabled

Answer: CD

NEW QUESTION 15
A customer reports that OnCommand Performance Manager shows that the workload on node-02 in a 4-node cluster has increased to a level that is higher than the threshold. The customer wants to avoid this issue becoming a performance problem.
Which two actions would result in achieving this goal? (Choose two.)

  • A. Use the volume move command to move one or more volumes to another aggregate that is owned by another node that is less utilized.
  • B. Use the storage aggregate relocation command to offload an aggregate to its partner.
  • C. Use the storage aggregate scrub command to verify the parity on the busy aggregates.
  • D. Physically move the shelf to another node that is less utilized.

Answer: AD

NEW QUESTION 16
A customer’s FAS8200 node1 went down an hour ago after a WAFL inconsistency error. All data is being served from partner node2, but the storage failover show command output is not showing a node1 as “Waiting for giveback”.
What is the corrective action for this situation?

  • A. Re-create the root aggregate on node1.
  • B. Boot the system and run the wafliron command on the inconsistent data aggregate.
  • C. From the LOADER prompt, run the wafliron command on the system’s root aggregate.
  • D. Boot the system and run the WAFL_check command on the inconsistent data aggregate.

Answer: A

NEW QUESTION 17
......

P.S. DumpSolutions.com now are offering 100% pass ensure NS0-592 dumps! All NS0-592 exam questions have been updated with correct answers: https://www.dumpsolutions.com/NS0-592-dumps/ (65 New Questions)


START NS0-592 EXAM