Q1. A server administrator is researching the purchase of SSD for a server. The administrator receives a report from the datacenter technician detailing current storage requirements and future growth planning estimates as follows:

ServerA: Current-15TB-Future-50% growth

ServerB: Current-20TB-Future-80% growth

Based on this report, which of the following represents the MINIMUM storage requirements needed?

A. ServerA-18TB, ServerB-24TB

B. ServerA-22TB, ServerB-22TB

C. ServerA-23TB, ServerB-36TB

D. ServerA-25TB, ServerB-40TB

Answer: C

Q2. A system administrator is tasked to setup a database server with failover clustering feature

enabled. One of the requirements is to have one database running at all times with data being synchronizedand replicated to the idle database in case the primary database server fails. Both servers will be monitored by a witness on a LUN. Which of the followingcluster techniques should be implemented to meet these requirements?

A. Active/Active

B. Active/Passive

C. Single Local Quorum

D. Passive/Passive

E. Shared Multiple Quorum

Answer: B

Q3. Two technicians are asked to install a 6U server at location U25 in a 40U server rack. The rack has been properly stabilized to the floor. Which of the followingtoolswouldBESTbe used to install the server?

A. A static strap.

B. A server lift.

C. A PDU.

D. A UPS.

Answer: B

Q4. Which of the following troubleshooting methods would be performed after resolving an issue?

A. Verify system connectivity

B. Implement the solution

C. Document findings

D. Establish theory

Answer: C

Q5. A network administrator installs a new web server and notices that the server was configured with one quad-port NIC. In order to properly provision the hardware resources, how should the NIC be configured?

A. Assign at least one IP address to each port

B. Assign multiple IP addresses to one port

C. Assign one IP address to the quad-port NIC

D. Assign a single IP address to all four ports

Answer: A

Q6. An administrator sees a message in the system console that a drive is bad in the single- volume JBOD storage array. A few minutes later, a user calls the help deskto report an inability to read a file from amapped drive.Which of the following should theadministratordo?

A. Swap out the failed drive and let the array rebuild.

B. Allow the array rebuild automatically using the hotspare.

C. Replace the failed drive and restore the data from the last backup.

D. Reseat the failed drive and restore the array using the parity drive.

Answer: C

Q7. Users in the accounting department report that they are unable to access a shared network drive used by all departments. Upon troubleshooting, a technician determines that three users in the marketing department, two in sales, five in human resources, and ten in IT are all successfully accessing the shared network drive. Which of the following is MOST likely causing the issue?

A. Corrupt user profiles

B. Incorrect NTFS group permissions

C. The share is unsecured

D. Excessive page filing on server

Answer: B

Q8. A technician has finished installing the operating system on a new server and needs to provide IP addressing information. The server will be connected to the DMZ network. Devices on thenetwork use a default gateway address of 192.168.55.1. Which of the following is a valid IP address for a server in the DMZ network?

A. IP: 192.168.55.1, NETMASK 255.255.255.0

B. IP: 192.168.55.5, NETMASK 255.255.255.128

C. IP: 192.168.55.155, NETMASK 255.255.255.128

D. IP: 192.168.55.255, NETMASK 255.255.255.0

Answer: B

Q9. A technician needs to install additional memory in a server to help resolve performance issues. Which of the following should the technician do FIRST?

A. Perform an impact analysis.

B. Follow change management procedures.

C. Install the additional memory.

D. Update system firmware.

Answer: B

Q10. An administrator hasbeentaskedwithconsolidatingsixindividual serversinto one blade enclosure. Theadministrator completed the task successfully.A week later, all of the bladeswould not boot properly. Which of the followingwould MOST likely be causing this issue?

A. The blade servers are faulty.

B. The network module on the blade enclosure is faulty.

C. The backplane of the enclosure is faulty.

D. The management modules in the enclosure are faulty.

Answer: C

Q11. A server technician is replacing a web server in an organization. The new server has two integrated NICs. Which of the following describes how the NICs should be configured for fault protection?

A. The NICs should be configured separately with one MAC address.

B. The NICs should be placed into a team with one MAC address.

C. The NICs should be configured separately with two MAC addresses.

D. The NICs should be placed into a team with two MAC addresses.

Answer: B

Q12. A system administrator notices that a server is consistently getting slower and less responsive the longer it has been since the last reboot. Once the server is rebooted, the system performs at the expected baseline, but starts slowing down again until the system is unresponsive. Which of the following is the MOST likely cause of this problem?

A. OS performance misconfiguration

B. Service/application memory leak

C. Incorrect server resource specifications

D. Corrupted application files

Answer: B

Q13. After starting an operating system installation from DVD, a system administrator goes to work on another task and comes back to find the server back at the installation start screen. Which of the following should be done to correct this problem?

A. Try installation again with a different DVD.

B. Modify the device boot order in the BIOS.

C. Monitor the operating system installation process completely this time.

D. Swap the hard drive with a known working one.

Answer: B

Q14. A server with a number of graphics cards installed was recently upgraded with additional graphics cards. Once the server is started, the system powers off unexpectedly. Prior to the upgrade, the server was stable and exhibited no odd behavior. Which of the following is the MOST likely cause of the problem?

A. The card device drivers are out of date and need to be updated.

B. The power supply cannot handle the additional power for the new cards.

C. The operating system does not recognize the new cards.

D. The cards are not compatible with the other server hardware.

Answer: B

Q15. A system administrator is given a server with an existing OS installed and four empty SAS bays. The system administrator is asked to set up a new data drive for testing with 100GB of data. For the best possible performance, which of the following should the system administrator select for the data storage?

A. SCSI

B. SATA

C. Solid state drive

D. Flash drive

Answer: C